What was found
R/W L/E PANEL 621PB HAS PULLED FASTENER HOLE (MARKED)<[01] IDENTIFIED PART AND MATERIAL IAW SRM 57-41-01-0I-4 FIGURES 1+3; TABLE 3; ITEM [1].<BR>FOUND DAMAGE TO BE OUT OF ALLOWABLE DAMAGE LIMITS IAW SRM 57-41-01-1A-1 PAR 4.A (5).<BR>A PERMANENT REPAIR WILL BE ACCOMPLISHED IAW SRM 51-70-04-2R-6 AS DIRECTED PER SRM 57-41-01-2R-1 PAR 4.B (2) AND TABLE 202.;09] FABRICATED UPPER AND LOWER SURFACE REPAIR PLIES AND INSTALLED USING BMS 8-301 CL1 LOT#JH2EAA8895. VACUUM BAGGED; LEAK CHECK GOOD USING VACUUM GAUGE ID:ATS2441 DUE:08/23 AND CURED UNDER HEAT LAMP USING THERMOMETER ID:ATS2209 DUE:10/23. UNBAGGED REPAIR PLIES; TRIMMED EXCESS MATERIAL AND CLEANED IAW SRM 51-70-04-2R-9 PARA 4.J-M<BR><BR>REQUESTING POST CURE NDI IAW SRM 51-70-04-2R-9 PARA 4.O.;[10] ADDITION TO ITEM 9. <BR>FABRICATED UPPER AND LOWER SURFACE REPAIR PLIES USING BMS 9-3 ST1581 LOT#1526805-2;[11] INSPECTED AND VERIFIED CORRECTIVE ACTIONS 7-10.<BR><BR>POST REPAIR UT INSPECTED PER 737NDT PART 4 51-00-02. NO DEFECTS FOUND. TOOL E650 ATS2342 DUE 07/2023.;[12] FABRICATED FOIL REPAIR PLY USING BMS 8-289 LOT#1511322-1 AND INSTALLED FOIL WITH BMS 5-128 LOT#JH3CA16476. VACUUM BAGGED; LEAK CHECK GOOD USING VACUUM GAUGE ID:ATS2798 DUE:06/24 AND SET TO CURE UNDER HEAT LAMP USING THERMOMETER ID:ATS2209 DUE:10/23; UNBAGGED FOIL; AND TRIMMED EXCESS MATERIAL IAW SRM 51-70-14-2R-3 PARA 4.A(3-5(A)11)).