What was found
L/W L/E PANEL 521JB HAS PULLED FASTENER HOLES (MARKED)<[01] IDENTIFIED PANEL MATERIAL IAW SRM 57-41-01-0I-4 FIG 4 TABLE 4 ITEM 1.<BR>FOUND DAMAGE TO 3EA FASTENER HOLES TO BE OUT OF ALLOWABLE LIMITS IAW SRM 57-41-01-1A-1 PARA 4.A(5).<BR>DAMAGE WILL BE REPAIRED IAW SRM 51-70-04-2R-9 PER SRM 57-41-01-2R-1 TABLE 202.<BR><BR>REMOVED 2EA BACKUP PLATES TO FACILITATE REPAIR IAW SRM 51-40-02-0G-0 PARA 4.E.<BR>REMOVED ENTIRE ALUMINUM FOIL BACKING TO FACILITATE REPAIR IAW SRM 51-70-14-2R-3 PARA 4.A(2)(B;C;E).<BR>REMOVED DAMAGE TO FASTENER LOCATIONS AND CLEANED REPAIR AREA IAW SRM 51-70-04-2R-9 PARA 4.A-C.;;[07] FABRICATED ALUMINUM FOIL PLY USING BMS 8-289 LOT# 1511322-1; INSTALLED WITH BMS 5-128 LOT#JH3CA16476; VACUUM BAGGED; LEAK CHECK GOOD WITH VACUUM GAUGE ID:ATS2798 CAL DUE 06/2024; CURED WITH THERMOMETER ID:ATS2208 CAL DUE 10/2023; UNBAGGED AND TRIMMED EXCESS MATERIAL IAW SRM 51-70-14-2R-3 PARA 4.A(3-5; 11)(A-L).