What was found
CORROSION ON AFT CARGO BAY FLOOR TO SIDEWALL SUPPORT AT STATIONS: 727+2; 727+6; 727C+7; 727C+11; 727C+19; 727D+3; 727D+5; 727D+6; 727D+8; 727D+10; LBL 22; WL 156.<[01] VERIFIED SRM 53-60-53-0I-2 FOR IDENTIFICATION AND SRM 53-00-53-1A-2 FOR ALLOWABLE DAMAGE.;[02] ALL STEPS COMPLETED;[03] THIS FAULT WILL BE ACCOMPLISHED ON CARD NUMBER TTG8Q00LHMM5.<BR>COMPLETED ALL MAINTENANCE ACTIONS.;[04] VERIFIED STEPS 1-10; CORRECTIVE ACTIONS 1-3<BR>VERIFIED MEASUREMENT TABLE<BR>VERIFIED SRM APPLICABILITY.