What was found
BS 328 FRAME CRACKED AT LOWER END JUST ABOVE FWD ENTRY DOOR UPPER SILL WEB LBL 40 WL 284.<[01] NO ALLOWABLE DAMAGE PERMITTED PER SRM 53-00-07-1A-1 ALLOWABLE DAMAGE 1 PAR 4.A <BR>DISCREPANCY TO BE CONFIRMED BY HFEC;REMOVE I.A.W SRM 51-10-02-0G-0 AND CONTACT ENGINEERING FOR REPAIR INSTRUCTIONS.;[02] ACCOMPLISHED HFEC SURFACE SCAN ON SUSPECTED CRACK AREA IAW 737 NDTM PART 6 CHAPTER 51-00-00 PROCEDURE 23. NO CRACKS NOTED.<BR><BR>EQUIPMENT USED: NORTEC 600 ID: ATS1465 CAL DUE: 09/2023;[03] AFTER FURTHER INVESTIGATION AND INSPECTED WITH NDI HFEC EQUIPMENT NO CRACK FOUND ON DISCREPANCY AREA;NO FURTHER ACTION NEEDED.;[04] VERIFIED STEPS 1; 2; 3.;[05] VERIFIED STEPS 1; 2; 3.