What was found
CORROSION AFT CARGO BAY SHIELD FWD OF CARGO DOOR AROUND MULTIPLE NUT PLATE HOLES BS767+3 TO BS794 RBL22 WL156<[01] CORROSION ON SHIELD WAS FOUND TO BE OUT OF LIMITS DUE TO NO LIMITS ARE GIVEN IN THE SRM. PART REPLACEMENT REQUIRED PER SRM 51-10-02.;[02] VERIFIED CORRECTIVE ACTION 1.;[03] REMOVED DAMAGED AFT CARGO BAY SHIELD FWD OF CARGO DOOR BS767 TO BS794 RBL22 WL156 IAW SRM 51-40-02-0G-0;[04] LOCATED AND DRILLED NEW AFT CARGO BAY SHIELD FWD OF CARGO DOOR BS767 TO BS794 RBL22 WL156 IAW SRM 51-40-05-0G-0 AND DWG146A0081;[05] VERIFIED STEPS 3 AND 4;[06] OK TO INSTALL;[07] VERIFIED CORRECTIVE ACTION 6<BR>OK TO INSTALL GIVEN;[08] INSTALLED AFT CARGO BAY SHIELD FWD OF CARGO DOOR BS767 TO BS794 RBL22 WL156 IAW SRM 51-40-02-0G-0 AND DWG146A0081;[09] VERIFIED CORRECTIVE ACTIONS 8 AND MEASUREMENT TABLE.