What was found
CORROSION ON FLOOR SUPPORT BS 949 RBL 51 WL 208<[01] VERIFIED APPLICABILITY PER SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1;[02] EVALUATED CORROSION ON FLOOR SUPPORT STA 949; RBL 51; WL 208 1'X0.600' INCH LOWEST MATERIAL REMOVED IS 0.040' ADJACENT TO ORIGINAL MATERIAL THICKNESS 0.080' FOUND TO BE OUT LIMITS I.A.W SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 PAR 4.C(2) (A) FIGURE 104/ALLOWABLE DAMAGE 1 DETAIL E<BR>TOOLS USED ON CORRECTIVE ACTION 2<BR>ATS2738<BR>S/N A22004095<BR>DUE 04/2024;[03] LOCATED AND DRILLED NEW FLOOR SUPPORT BS946-BS 967 RBL 51 WL 208 I.A.W SRM 51-40-05-0G-0 AND BOEING DWG 147A5650. INTERCOSTAL BEING REMOVED AND TO BE INSTALL ON COSTUMER CARD TTG8Q00LSY1R STEP 5<BR>COMPLETED TASK;[04] VERIFIED CORRECTIVE ACTIONS 3;[05] MISSING FAILURE TYPE AND MEASUREMENT TABLE WILL BE CAPTURED ON [TTG8Q00LX996]