What was found
CRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 BL 1 AT FWD GALLEY AREA 2023-409628<[01] TOOL USED DIGITAL CALIPER P/N: 500-752-20; S/N: B21037208; DUE DATE: 04-MAR-24.;[02] REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 BL 1 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02-0G-0 ITEM 9 AND SRM 51-40-05-0G-0 AND DWG #141A5400 REV -. SEE INDIVIDUAL SIGNS-OFF BELLOW.;[03] CORRECTED STEP 2 <BR>REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 BL 1 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02-0G-0 ITEM 9 AND SRM 51-40-02-0G-0 AND DWG #141A5400 REV -. SEE INDIVIDUAL SIGNS-OFF BELLOW.;[04] REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 BL 1 AT FWD GALLEY AREA IAW B737-700 SRM 51-10-02-0G-0 ITEM 9 AND SRM 51-40-02-0G-0 AND DWG #141A5400 REV -. SEE INDIVIDUAL SIGNS-OFF BELLOW. RII