What was found
(A204 DOT 14) AFT CARGO STA 727I+4 RBL 23; WL 161; Z-ANGLE HAS CORROSION AROUND FASTNER HOLE.<[01] REMOVED CORROSION OF Z- ANGLE AND CHECK WITH MAGNIFYING GLASS IAW SRM 51-10-02-0G-0 ITEM 14;[02] EVALUATED DAMAGE ;ORIG.'T' .040 MATERIAL REMAINING.032 LOSS.008 FOUND OUT OF LIMITS IWA SRM 53-00-53-1A-2 TOOL USED UT AAR#36644 DUE 08/02/23;[03] ENTER IN ERROR : TOOL USED AAR#36649 DUE 08/02-23;[04] REMOVED DAMAGED PART OF THE SIDEPLATE I.A.W. SRM 53-00-53-2R-5;[05] C/W;[06] VERIFIED MATERIAL FOR -1 ZEE CHANNEL SIDEPLATE AND -2 SPLICE SIDEPLATE MATERIAL BAC1496-377 7075-T62 ATAG A120480 IAW SRM 53-00-53-2R-5 TABLE 201;[07] VERIFIED ITEM 6;[08] STARTED FABRICATING NEW -1 ZEE CHANNEL SIDEPLATE IAW SRM 53-00-53-2R-5;[09] VERIFIED ITEM 8;[10] COMPLETED FABRICATION OF Z-ANGLE AND SPLICE IAW SRM 53-00-53-2R-5 FIGURE 202.;[11] VERIFIED STEP 10 C/W<BR>OK TO TREAT AND PRIME;[12] APPLIED CHEMICAL CONVERSION AND PRIMER IAW SRM 53-00-53-2R-5 SECTION 4. I; J.;[13] STEP 12 C/W;[14] OK TO INSTALL SPLICE PARTS AND NUT PLATES;[15] INSTALLED NUTPLATES ON NEW Z-ANGLE SECTION IAW SRM 53-00-53-2R-5 SECTION 4. K.;[16] STEP 15 C/W;[17. Z ANGLE HAS BEEN CUT AT STA 727H+12' TO STA 767 R/H <BR>OK TO INSTALL;[21] INSTALLED ALL REPAIR PARTS IAW SRM 53-00-53-2R-5 FIG 202;[22] NEED OK TO APPLY CIC REPAIR AREA;[23] VERIFIED ITEM 21;[24] OK TO CIC;[25] CICED AREA I.A.W SRM 53-00-53-2R-5;[26] STEP 25 C/W AUDIT C/W