What was found
AFT GALLEY FLOOR STRUCTURE STA. 947.5 LBL 56; AFT ENTRY 'Z' ANGLE HAS CORROSION AROUND NUT PLATE HOLES. AREA MARKED IS ADJACENT TO 2 HI LOCKS AND NOT AROUND NUTPLATE HOLES<[01] CORRECTED LOCATION TO STA 947.5 ON MEASUREMENTS.;[02] REMOVED CORROSION WITHIN LIMITS PER SRM53-70-51-1A-1. OK TO TREAT AND PAINT.;[03] REMOVED CORROSION WITHIN LIMITS PER SRM 51-10-02 AND 53-70-51-1A-1. OK TO TREAT AND PAINT.;[04] REMOVED CORROSION WITHIN LIMITS PER SRM 51-10-02 AND 53-70-51-1A-1. OK TO TREAT AND PAINT. C/W INSPECTION;[05] REMOVED CORROSION WITHIN LIMITS PER SRM 51-10-02 AND 53-70-51-1A-1. TREATED AND PRIMED AREA PER SRM 51-20-01 AND AMM 51-21-72.;[06] REMOVED CORROSION WITHIN LIMITS PER SRM 51-10-02 AND 53-70-51-1A-1. TREATED AND PRIMED AREA PER SRM 51-20-01 AND AMM 51-21-72 C/W INSPECTION;[07] REMOVED CORROSION WITHIN LIMITS PER SRM 51-10-02 AND 53-70-51-1A-1. TREATED AND PRIMED AREA PER SRM 51-20-01 AND AMM 51-21-72 C/W INSPECTION