What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL46 FWD GALLEY AND LAV 2023-404973<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL46 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 141A5400 SHEET: 26 REV:- SEE INDIVIDUAL SIGN OFF BELOW.;[02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BS312 TO BS328 AT LBL46 FWD GALLEY AND LAV IAW B737-700 SRM 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 141A5400 SHEET: 26 REV:- SEE INDIVIDUAL SIGN OFF BELOW.<BR>RII