As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CRACK FOUND ON CENTER TANK UPPER ATTACH ANGLE AT STA 663 RBL 45 ( WL 193 )<[01] REMOVED THE REPAIR THAT WAS ORIGINALLY INSTALLED PER NRC G098319. INSTALLED A NEW REPAIR PER EA 23-157-02220 [SRM 57-10-10-2R-3 (REPAIR 3 ALTERNATE 2) AND SRM 57-10-10-2R-6 (REPAIR 6)]. INSPECTION THRESHOLD DEFINED IN EA 23-157-02220-DTI.;[02] VERIFIED STEP 1<BR>AUDIT CW