What was found
FWD. CARGO BILGE; L/H TRANS. ANGLE FASTENER HOLES CORRODED FROM BS 500D-500E.<[01] CORROSION FOUND TO BE OUT OF LIMITS PER SRM 53-00-53-1A-2;[02] INSPECTED THE WORK PERFORMED ON C/A #1; NO DEFECTS NOTED.;[03] REMOVED DAMAGED SECTION OF L/H SIDEPLATE FROM STA 500B+10 TO 500E+9.5 PER SRM 53-00-53-2R-5.;[04] C/W INSPECTION.;[05] FABRICATED AND LOCATED REPAIR PARTS PER SRM 53-00-53-2R-5.;[06] NOTE ONLY: DURING THE ACCOMPLISHMENT OF SRM 53-00-53-2R-5 (REPAIR 5) INSTALL FLOOR BOARD FASTENERS BACS12ER3K10 OR BACS12GP3L10 OR BACS12GR3L10 SCREWS<BR>PER REQUIREMENTS OF STEP 7 OF EA# M-22-153-01-550.;[07] INSTALLED REPAIR PARTS PER SRM 53-00-53-2R-5;[08] INSTALLED REPAIR PARTS PER SRM 53-00-53-2R-5 RII;[09] REPAIRED PER SRM 53-00-53-2R-5