As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
B SYS HYD FAILURE FOUND PRESSURE DECK FLOW LIMITER ASSEMBLY LEAKING FROM UNION PACKING. CREW REPORTS IMMEDIATELY TURNED BOTH EDP & EMDP TO OFF POSITION. DUE TO HYDRAULIC QUANTITY DEPLETING.<[01] FOUND CRACKED FITTING; REMOVED AND REPLACED T/E FLAP FLOW LIMITER; AMM IAW 27-51-67. RAN ENGINES AND ALL FLIGHT CONTROLS; PER AMM 71-00-00; SERVICED HYDRAULIC QUANITY PER AMM 12-12-00; ALL SYSTEMS RESTORED.