What was found
CRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 294.5 TO BS 312 RBL 16 AT FWD GALLEY AREA 2023-422291<[01] REPLACED INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 294.5 TO BS 312 RBL 16 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 141A5400; SHEET 45 AND REV: A SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 294.5 TO BS 312 RBL 16 AT FWD GALLEY AREA IAW B737-700 SRM 51-40-02 AND DWG 141A5400; SHEET 45 AND REV: A; RII SEE INDIVIDUAL SIGN OFF BELOW