What was found
CRACK FLOOR STRUCTURE FITTING LOCATED BS947.5 AND STR26R AT AFT CARGO COMPARTMENT 2023-431262<[01] REPLACED FITTING AND FASTENERS LOCATED BS947.5 AND STR26L AT AFT CARGO COMPARTMENT IAW B737-700 SRM 51-40-02-0G-0; SRM 51-10-02-0G-0 Ï¿½TEM 9 AND DWG 149A8103 SHEET 7 REV A. SEE INDIVIDUAL SING-OFFS BELOW;[02] REPLACED FITTING AND FASTENERS LOCATED BS947.5 AND STR26L AT AFT CARGO COMPARTMENT IAW B737-700 SRM 51-40-02-0G-0; SRM 51-10-02-0G-0 Ï¿½TEM 9 AND DWG 149A8103 SHEET 7 REV A. SEE INDIVIDUAL SING-OFFS BELOW ITEM RII