What was found
CRACK ON SUPPORT ANGLE LOCATED BS 294.5 AT LEVEL STR 17R FWD GALLEY AREA 2023-422372<[01] REPLACED SUPPORT ANGLE LOCATED BS 294.5 AT LEVEL STR 17R FWD GALLEY AREA IAW B737-700 SRM 51-10-02 ITEM 9 AND DRAWING # 141A8310 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.;[02] CORRECTED STEP 1. REPLACED SUPPORT ANGLE LOCATED BS 294.5 AT LEVEL STR 17R FWD GALLEY AREA IAW B737-700 SRM 51-10-02-0G-0 ITEM 9 AND DRAWING # 141A8310 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.;[03] REPLACED SUPPORT ANGLE LOCATED BS 294.5 AT LEVEL STR 17R FWD GALLEY AREA IAW B737-700 SRM 51-10-02-0G-0 ITEM 9 AND DRAWING # 141A8310 REV: -. SEE INDIVIDUAL SIGN OFF BELOW.<BR>CERTIFIED AS RII