What was found
CORROSION FLOOR STRUCTURE ON STRAP LOCATED BS1040 BETWEEN BL0 TO LBL 43 AND WL 208.1 AT AFT GALLEY AREA 2023-422406<[01] REPLACED STRAP LOCATED BS1040 BETWEEN BL0 TO LBL 43 AND WL 208.1 AT AFT GALLEY AREA AND FASTENERS I.A.W B737-700 SRM 51-40-02 AND DWG: 140A9870 SHEET: 5 REV: A SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED STRAP LOCATED BS1040 BETWEEN BL0 TO LBL 43 AND WL 208.1 AT AFT GALLEY AREA AND FASTENERS I.A.W B737-700 SRM 51-40-02 AND DWG: 140A9870 SHEET: 5 REV: A SEE INDIVIDUAL SIGN OFF BELOW