What was found
CRACK ON STUB FRAME LOCATED BS 294.5 BTW STR 9R TO STR 11R CUTOUT AT FWD SERVICE DOOR 2023-422409<[01] REPLACED STUB FRAME LOC. BS 294.5 BTW STR 9R TO STR 11R CUTOUT AT FWD SERVICE DOOR IAW SRM B737-700 51-10-02. SRM 51-40-02; DRAWING: 141A8370 REV. D. SEE INDIVIDUAL SIGN-OFF BELOW.;[02] REPLACED STUB FRAME LOC. BS 294.5 BTW STR 9R TO STR 11R CUTOUT AT FWD SERVICE DOOR IAW SRM B737-700 51-10-02. SRM 51-40-02; DRAWING: 141A8370 REV. D.RII ; SEE INDIVIDUAL SIGN-OFF BELOW.