What was found
CRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 24.75 AT CENTER SECTION 2023-431108<[01] REPLACED INTERCOSTAL AND FASTENERS LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02-0G-0 AND SRM 51-10-02 -0G-0 ITEM 9. SEE INDIVIDUAL SIGN OFF BELOW;[02] CERTIFIED AS RII <BR>REPLACED INTERCOSTAL AND FASTENERS LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO LBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02-0G-0 AND SRM 51-10-02 -0G-0 ITEM 9. SEE INDIVIDUAL SIGN OFF BELOW