What was found
CRACK ON INTERCOSTAL LOCATED FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION 2023-431107<[01] INSTALLED NEW INTERCOSTAL AND FASTENERS LOC.FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 143A0060 SHEET 46 REV -;[02] CORRECTED STEP 1 <BR>REPLACED INTERCOSTAL AND FASTENERS LOC.FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 143A0060 SHEET 46 REV -;[03] CORRECTED STEP 2 <BR>REPLACED INTERCOSTAL AND FASTENERS LOC.FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 143A0060 SHEET 36 REV A;[04] RII ITEM <BR>REPLACED INTERCOSTAL AND FASTENERS LOC.FLOOR STRUCTURE BS 540 BTW BL 0 TO RBL 24.75 AT CENTER SECTION IAW B737-700 SRM 51-40-02 SRM 51-10-02 ITEM 9 AND DWG 143A0060 SHEET 36 REV A