What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BS 695 RBL 24.75 CENTER SECTION 2023-431116<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112031023; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N P3015GOES00000; S/N 112811019; DUE DATE: 25-JAN-24 AND TEMPERATURE CONTROLLER: P/N: 38615K71; S/N: AE-40586; DUE DATE: 09-AUG-23.;[02] REPLACED ANGLE LOCATED AT BSTA 695 RBL 24.75 CENTER SECTION IAW SRM B737-700 51-40-02; SRM 51-10-02 ITEM 9 AND DWG 273A9110 REV-A<BR>SEE INDIVIDUAL SIGNOFFS BELOW;[03] CERTIFIED STEP 2 COMPLETED