What was found
AFT AREA OF FOWARD CARGO BS540 STR 26R CRACKED<[01] VERIFIED APPLICABILITY SRM 53-00-03-2R-1<BR>CUT AND REMOVED THE DAMAGED AREA ON STRINGER 26R BS 540 PER SRM 53-00-03-2R-1 CUT AREA ON BS 511;[02] VERIFIED CORRECTIVE ACTION 1;[03] REQUEST HFEC EDDY CURRENT INSPECTION OF THE REPAIR AREA TO MAKE SURE THAT ALL OF THE DAMAGE IS REMOVEDRECIVED NEW STRINGER SECTION FROM OSS ITEM HFAB53-STR-010 CUSTOMER RO NO 929671-SWA AND HAT SECTION ITEM HFAB53-HC-011 CUSTOMER RO NO 929731-SWA<BR>LOCATED AND DRILLED STRINGER SECTION AND HAT SECTION ON AFT AREA OF FWD CARGO BS 540 STR 26R PER SRM 53-00-03-2R-1.<BR>APLIED CHEMICAL CONVERSION COATING ON STRINGER SECTION AND HAT SECTION OK TO APPLIED PRIMER;[06] RECIVED NEW STRINGER SECTION FROM OSS ITEM HFAB53-STR-010 CUSTOMER RO NO 929666-SWA AND HAT SECTION ITEM HFAB53-HC-011 CUSTOMER RO NO 929729-SA<BR>LOCATED AND DRILLED STRINGER SECTION AND HAT SECTION ON AFT AREA OF FWD CARGO BS 540 STR 26R PER SRM 53-00-03-2R-1.<BR>APPLIED CHEMICAL CONVERSION COATING AND PRIMED ON STRINGER SECTION AND HAT SECTION.<BR>OK TO INSTALL REPAIR PARTS;[07] VERIFIED CORRECTION ACTION ITEM 5 & 6; LOCATED & DRILLED. OK TO INSTALL GIVEN.;[08] INSTALLED ALL REPAIR PARTS PER SRM 53-00-03-2R-1;[09] INSTALLED ALL REPAIR PARTS PER SRM 53-00-03-2R-1 PART 4.K FIGURE 205.ALL MAINTENANCE ITEMS COMPLETE;[19] VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.