What was found
AFT AREA OF FOWARD CARGO BS540 STR 25L CRACKED<[01] VERIFIED APPLICABILITY SRM 53-00-03-2R-1<BR>CUT AND REMOVED THE DAMAGED AREA ON STRINGER 25L BS 540 PER SRM 53-00-03-2R-1 CUT AREA ON BS 515;[02] VERIFIED CORRECTIVE ACTION 1;[03] REQUEST HFEC EDDY CURRENT INSPECTION OF THE REPAIR AREA TO MAKE SURE THAT ALL OF THE DAMAGE IS REMOVED;[04] HFEC INSPECTED REPAIR AREA IAW 737 NDTM PART 6; 51-00-00 PROCEDURE 23.<BR>NO CRACKS NOTED.<BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS1465 CAL DUE: 09/23;[05] RECIVED NEW STRINGER SECTION FROM OSS ITEM HFAB53-STR-010 CUSTOMER RO NO 929671-SWA AND HAT SECTION ITEM HFAB53-HC-011 CUSTOMER RO NO 929731-SWA<BR>LOCATED AND DRILLED STRINGER SECTION AND HAT SECTION ON AFT AREA OF FWD CARGO BS 540 STR 25L PER SRM 53-00-03-2R-1.<BR>APLIED CHEMICAL CONVERSION COATING ON STRINGER SECTION AND HAT SECTION OK TO APPLIED PRIMER;[06] VERIFIED CORRECTION ACTION ITEM 5 COMPLETE.;[07] APPLIED PRIMED ON STRINGER SECTION AND HAT SECTION PER SRM 53-00-03-2R-1<BR>OK TO INSTALL REPAIR PARTS;[08] VERIFIED CORRECTION ACTION ITEM 7. OK TO INSTALL GIVEN.;[09] INSTALLED ALL REPAIR PART PER SRM 53-00-03-2R-1.;[10] INSTALLED ALL REPAIR PARTS PER SRM 53-00-03-2R-1 PART 4.K FIGURE 205.;VERIFIED MEASUREMENT TABLE AND TASK CARD COMPLETE.