What was found
CORROSION ON AFT SHIELD AT BS 500-500A RBL 25 WL 156<[01] ENTERED MEASUREMENTS;[02] SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS DAMAGE EVALUATION.<BR>NO ALLOWABLE DAMAGE FOUND IN 737-700 SRM FOR THIS PART.<BR>REPAIR BY REPLACEMENT SRM 51-10-02-0G-0 STEP 9;[03] VERIFIED CORRECTIVE ACTION STEP 2;[04] VERIFIED MEASUREMENT TABLE;[05] DRILLED AND LOCATED AND INSTALLED A-NUTS ON REPLACEMENT PART. IAW DWG 143A0080 ID0041; SRM 51-40-05; SRM 51-40-06; SRM 51-40-08; SRM 51-40-02.;[06] REQUEST OK TO INSTALL NEW SHIELD.;[07] VERIFIED CORRECTIVE ACTION #5.<BR>VERIFIED OK TO INSTALL NEW SHIELD.;[08] INSTALLED NEW SHIELD AT FCB BETWEEN BS 492 TO 500A ;RBL 25 ; WL 156 IAW SRM 51-40-02 AND DWG:143A0080; ID: 0041 ;REV:-;[09] VERIFIED CORRECTIVE ACTION #8.