What was found
AREA AFT OF FWD CARGO BAY HAS A CRACKED STRINGER AT THE AFT FASTENER; STR. 24R BS 520-540 WL 156<[01] EVALUATED CRACK AT FCB STRINGER 24R/H BS 539 DAMAGE FOUND TO BE OUT LIMITS IAW SRM 53-00-03-1A FIG 103 DETAIL A.;[02] VERIFIED APPLICABILITY FOR STR 24R/H AT FCB IAW SRM 53-00-03-2R-1 PAR 4. FIG 205;[03] CUTOUT AND REMOVED DAMAGE AT STRINGER SECTION 24R/H BETWEEN BS 500D+11' TO BS 539 IAW SRM 53-00-03-2R-1 PAR 4 STEPS A-B.;[04] UPDATE STEP 1 AND 2.RECEIVED NEW STRINGER SECTION P/N:HFAB53-STR-011;LOT:1533645-1;PO/N:927987/1 AND LOCATED AND DRILLED AT FCB STR 24R/H BETWEEN BS 500D+11' TO BS 539 AND APPLIED CHEMICAL CONVERISON COATING ON STRINGER SECTION IAW SRM 53-00-03-2R-1 FIG 205. REQUEST OK TO PRIME STRINGER SECTION.;[11] RECEIVED NEW STRINGER SECTION P/N:HFAB53-STR-011;LOT:1533645-1;PO/N:927987/1 ANDLOCATED AND DRILLED NEW PART IAW SRM 53-00-03-2R-1 REPAIR 1 AND SRM 51-40-05-0G-0.<BR>APPLIED CONVERSION COATING IAW AMM 51-21-41-370-803.<BR>APPLIED PRIMER IAW AMM 51-21-72-370-804.;[16] VERIFIED CORRECTION ACTION ITEM 15.;] INSTALLED REPAIR PARTS AT FCB BETWEEN BS 500D+5' TO BS 539 STRINGER 24 R/H IAW SRM 53-00-03-2R-1 REPAIR 1; FIG 205.