What was found
FWD SHIELD IS CORRODED FROM BS 767-767+16 RBL 20 WL 157<[01] UPDATED MEASUREMENTS TABLE;[02] NOT FOUND ALLOWABLE ON SRM; PART WILL BE REPLACE PER SRM 51-10-02-0G-0; STEP 9;[03] REMOVED FWD SHIELD FROM AFT CARGO COMPARTMENT FROM BS 767 TO BS 794.25 IAW SRM 51-40-02-0G-0.<BR>LOCATED AND DRILLED NEW FWD SHIELD IAW SRM 51-40-05-0G-0 AND DWG 146A0081;ID:0025; REV:A; REQUEST OK TO INSTALL;[04] VERIFIED MEASUREMENT TABLE. OK TO INSTALL PART;[05] OK TO INSTALL PART;[06] STARTED TO INSTALL IAW SRM 51-40-02 DWG 146A0081;ID:0025; REV:A;[07] APPLIED TOP COAT BMS-10-11 TYPE 2 IAW AMM 51-21-73-370-804 AT SHIELD BEFORE INSTALLED;[08] VERIFIED CORRECTIVE ACTION 7;[09] APPLIED CIC AT SHIELD IAW SOPM 20-41-05.REQ. OK TO INSTALL SHIELD;[10] VERIFIED CORRECTIVE ACTION 9.<BR>OK TO INSTALL SHIELD;[11] INSTALLED NEW SHIELD IAW SRM 51-40-02-0G-0 AND DWG 146A0081 REV:A;[12] VERIFIED CORRECTIVE ACTION 11;[13] VERIFIED MEASUREMENT TABLE