What was found
FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 727E+13 - 787+19 RBL 20 WL 156<[01] UPDATED MEASUREMENTS TABLE;[02] FOUND UNDER INVESTIGATION LOCATION IS BS 727E+13 TO BS 747+19; RBL 20; WL 156;[03] SRM 53-00-53-1A-2 IS APPLICABLE FOR THIS;[04] BLENDED CORROSION ON FLOOR TO SIDEWALL SUPPORT HAS CORROSION BS 727E+13 - 747+19 RBL 20 WL 156;<BR>WORK AREA : BS 727E+1.5'; L 0.600' X W 0.600' X D 0.010'.<BR>BS 727E+2'; L 0.900' X W 0.700' X D 0.010; <BR>BS 727E+19'; L1.0' X W 0.600' X D 0.010'.<BR>BS 747+2'; L 1.0' X W 0.800' X D 0.009'.<BR>BS 747+10'; L 1.0' X W 0.700' X D 0.011'.<BR>BS 747+19'; L 1.0' X W 0.700' X D 0.0900'; FOUND OUT OF LIMITS IAW SRM 53-00-52-1A-2.<BR>USED DEPTH GAGE : ID:ATS2472;DUE: 12/31/2023;[05] WORK WILL BE ACCOMPLISH ON CUSTOMER CARD NBR: TTG8Q00M0TZB;[06] VERIFIED ITEMS 2;3;4. <BR>VERIFIED OUT OF LIMITS.;[07] VERIFIED CORRECTIVE ACTION 5 AND MEASUREMENT TABLE