What was found
FWD CABIN SERVICE DOOR SURROUND LOWER STUB FRAME CRACKED BS294 RBL54 WL209.<[01] VERIFIED SRM 53-10-15-1A-2 IS APPLICABLE FOR ALLOWABLE DAMAGE TO FSD SURROUND STRUCTURE.;[02] CONCUR WITH APPLICABILITY OF SRM 53-10-15-1A-2.;[03] REMOVED CLIP P/N 141A8312-3 PER SRM 51-40-02 FOR ACCESS.<BR>REQUEST NDI TO VERIFY CRACK(S) AND MARK ENDS.;[04] HFEC INSPECTED AREA IAW 737 NDTM PART 6; 51-00-00 PROCEDURE 23.<BR>NO CRACKS NOTED.<BR>EQUIP USED:<BR>-NORTEC 600 ID: ATS1465 CAL DUE: 09/23;[05] UPDATED MEASUREMENT TABLE.<BR>UPON FURTHER INVESTIGATION; NO CRACK FOUND IN FSD BS 294 STUB FRAME; RBL 54; WL 209.;[06] REQUEST OK TO REINSTALL CLIP P/N 141A8312-3.;[07] OK TO REINSTALL CLIP P/N 141A8312-3 GIVEN.;[08] INSTALLED CLIP PER SRM 51-40-02; DWG# 141A8310 REV-; AND DWG# 140A9810 REV A.;[09] VERIFIED CORRECTIVE ACTION 8;[10] VERIFIED MEASUREMENT TABLE