What was found
CRACKED INTERCOSTAL AT FWD CABIN BS291 BL0 WL208.<[01] VERIFIED APPLICABILITY FOR SRM 53-10-51-1A-1 ALLOWABLE DAMAGE 1.;[02] CRACK FOUND TO BE OUT OF LIMITS PER SRM 53-10-51-1A-1; PAR. 4.B.(1).(A). FIG. 105; DETAIL A.<BR>REMOVED INTERCOSTAL FROM BS277 - BS294; WL208; BL0 PER SRM 51-40-02-0G-0.<BR>RECEIVED FROM; TOOL ROOM NEW INTERCOSTAL P/N 141A5410U3.<BR>LOCATED AND DRILLED PER SRM 51-40-05-0G-0 AND BOEING DWG 141A5400; OK TO INSTALL.;[03] MEASUREMENTS TABLE UPDATED.;[04] VERIFIED CORRECTIVE ACTION #1; #2.<BR>VERIFIED OK TO INSTALL NEW INTERCOSTAL.;[05] INSTALLED INTERCOSTAL BETWEEN BS277 - BS294; WL208; BL0 PER SRM 51-40-02-0G-0 AND BOEING DWG. 141A5400.;[06] VERIFIED CORRECTIVE ACTION #5.;[07] VERIFIED MEASUREMENTS.