What was found
CRACKED INTERCOSTAL AT FWD CABIN BS344+9 LBL12 WL208.<[01] REMOVED INTERCOSTAL AT FWD CABIN BS 344+9 LBL12 WL208 IAW SRM 51-40-02;[02] UPDATED MEASUREMENT TABLE;[03] CERTIFY ACTION #1;[04] SRM DOES NOT HAVE REPAIR LIMITS FOR CRACKED INTERCOSTALS. OUT OF LIMITS. REMOVE AND REPLACE IAW SRM 51-10-02-0G-0 STEP #9.;[05] LOCATED AND DRILLED NEW INTERCOSTAL AT BS344- BS360 LBL12 WL208 IAW SRM 51-40-05-0G-0; DWG 141A5400 SHT 43; OK TO INSTALL;[06] VERIFIED CORRECTIVE ACTION ITEMS 4 AND 5.<BR>OKAY TO INSTALL NEW INTERCOSTAL IS GIVEN.;[07] STARTED FASTENER INSTALLATION IAW SRM 51-40-02-0G-0;[08] INSTALLED 100% OF FASTENERS AT NEW INTERCOSTAL AT BS 344 TO BS 360 LBL12 WL 208 PER SRM 51-40-02-0G-0; DWG 141A5400 SHT 43.;[09] VERIFIED CORRECTIVE ACTION 8;[10] VERIFIED MEASUREMENT TABLE