What was found
CRACKED INTERCOSTAL AT PASSENGER CABIN BS380+14 BL0 WL208.<[01] FOUND CRACK ONLY AT UPPER ANGLE OF INTERCOSTAL. SRM DOES NOT HAVE ALLOWABLE DAMAGE LIMITS FOR CRACKED ANGLE. OUT OF LIMITS. REMOVE AND REPLACE IAW SRM 51-10-02-0G-0 STEP #9.;[02] REMOVED ANGLE FROM INTERCOSTAL AT PASSENGER CABIN BS 380- BS 400 BL 0 WL 208 PER SRM 51-40-02-0G-0.;[03] RECEIVED FROM TOOL ROOM NEW ANGLE P/N 143A5410-170 S/N BN 392603. LOCATED AND DRILLED NEW ANGLE PER SRM 51-40-05-0G-0 AND DWG 143A5400. REQUEST OK TO INSTALL.;[04] VERIFIED CORRECTIVE ACTION #3.<BR>VERIFIED OK TO INSTALL NEW INTERCOSTAL.;[05] INSTALLED NEW ANGLE AT PASSENGER CABIN BS 380- BS 400 BL 0 WL 208 PER SRM 51-40-02-0G-0 AND DWG 143A5400.;[06] VERIFIED CORRECTIVE ACTION #5.;[07] VERIFIED MEASUREMENTS.