What was found
CORROSION ON AFT ENTRY DOOR MOP SILL BS 960-986 LBL 54 WL 208.<[01] REMOVED CORROSION ON MULTIPLE AREAS OF AFT ENTRY DOOR MOP SILL BS 960 - BS 986 LBL 54 WL 208 IAW SRM 51-10-02; ORIGINAL MATERIAL THICKNESS IS 0.080' IAW SRM 53-70-15-1A-1; MAXIMUM MATERIAL REMOVED IS 1.125'X.12'X0.012' REMAINING THICKNESS 0.068'; BLENDED AREA FOUND TO BE OUT LIMITS IAW SRM 53-70-15-1A-1;REMOVED CORROSION ON MULTIPLE AREAS OF AFT ENTRY DOOR MOP SILL BS 960 - BS 986 LBL 54 WL 208 IAW SRM 51-10-02; ORIGINAL MATERIAL THICKNESS IS 0.080' IAW SRM 53-70-15-1A-1; MAXIMUM MATERIAL REMOVED IS 0.012' BLEND AREA OF 1.125'X 12' REMAINING THICKNESS 0.068'; BLENDED AREA FOUND TO BE OUT LIMITS IAW SRM 53-70-15-1A-1;REMOVED ON AFT ENTRY DOOR MOP SILL BS 960-986 LBL 54 WL 208 I.A.W SRM 51-40-02-0G-0;[05] LOCATED AND DRILLED NEW AED MOPSILL P/N147A8540U7 I.A.W SRM 51-40-05-OG-0 AND BOEING DWG 147A8501 OK TO INSTALL;[06] LOCATED AND DRILLED NEW AED MOPSILL P/N147A8540U7 I.A.W SRM 51-40-05-OG-0 AND BOEING DWG 147A8501 REV A OK TO INSTALL;[07] VERIFIED CORRECTIVE ACTION ITEMS 4-6; OK TO INSTALL.;[08] PARTIALLY INSTALLED AFT ENTRY DOOR MOP SILL BS 960-986 LBL 54 WL 208 IAW BOEING DWG 147A8501 REV A.;[09] PARTIALLY INSTALLED AFT ENTRY DOOR MOP SILL BS 960-986 LBL 54 WL 208 IAW BOEING DWG 147A8501 REV A AND SRM 51-40-02-0G-0; INSTALLED AFT ENTRY DOOR MOPSILL BS 894-1006 LBL 54 WL 208 IAW SRM 51-40-02-0G-0 AND DWG 147A8501.;