What was found
CRACKED INTERCOSTAL TOP ANGLE BS 380-400 LBL 14 WL 208.<[01] REMOVED CRACKED INTERCOSTAL TOP ANGLE BS 380-400 LBL 14 WL 208 PER SRM 51-40-02-0G-0 4.E.; SRM 51-40-02-0G-0 7.D.(6) & BOEING DRAWING 143A5400.;[02] UPDATED MEASUREMENT TABLE;[03] UPON FURTHER INVESTIGATION PART HAS NO ALLOWABLE DAMAGE PER SRM 50-10-02-0G-0 STEP 9. AND WILL REQUIRE REPLACEMENT.;[04] UPON FURTHER INVESTIGATION PART HAS NO ALLOWABLE DAMAGE PER SRM 51-10-02-0G-0 STEP 9. AND WILL REQUIRE REPLACEMENT.;[05] VERIFIED CORRECTIVE ACTION ITEMS 1-4.;[06] RECEIVED; LOCATED AND DRILLED NEW ANGLE LOT # 1534988-1 CUSTOMER RO NO: 930122-SWA IAW SRM 51-40-05 AND DWG 143A5400 REV: A.;[07] VERIFIED CORRECTIVE ACTIONS 6<BR>OK TO PRIMER AND CHEMICAL CONVERSION APPLICATION GIVEN;[08] APPLIED CHEMICAL CONVERSION COATING AND PRIMER ON NEW INTERCOSTAL TOP ANGLE BS 380-400 LBL 14 WL 08 IAW SRM 51-20-01 AND AMM 51-21-72-370-804;(OK TO INSTALL;[09] VERIFIED COMPLETION OF CORRECTIVE ACTIONS 8<BR>OK TO INSTALL INTERCOSTAL GIVEN;[10] INSTALLED NEW INTERCOSTAL TOP ANGLE BS 38-400 LBL 14 WL 208 LOT # 1534988-1 CUSTOMER RO NO: 930122-SWA. IAW SRM 51-40-02 AND DWG 141A5400 REV:A;[11] VERIFIED COMPLETION OF CORRECTIVE ACTIONS 10.;[12] APON FURTHER INVESTIGATION PART HAS NO ALLOWABLE DAMAGE PER SRM 51-10-02-0G-0 STEP 9. AND WILL REQUIRE REPLACEMENT. REMOVED & INSTALLED NEW INTERCOSTAL TOP ANGLE BS 38-400 LBL 14 WL 208 LOT # 1534988-1 CUSTOMER RO NO: 930122-SWA. IAW SRM 51-40-02 AND DWG 141A5400 REV:A