What was found
CRACKED INTERCOSTAL BS 277-294 RBL 1 WL 208.<[01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS IAW SRM 53-10-51-1A-1 ALLLOWABLE DAMAGE 1 AND IDENTIFICATION IAW SRM 53-10-51-01-2 IDENTIFICATION 2.<BR>EVALUATED CRACKED INTERCOSTAL L: 0.890' AND FOUND OUT ALLOWABLE DAMAGE LIMITS IAW SRM 53-10-51-1A-1 ALLLOWABLE DAMAGE 1 FIGURE 105 DETAIL A AND K. TOOL USED CALIPER ID: ATS2883 CAL DUE 04/024;[02] REMOVED INTERCOSTAL LOCATED AT BS 277-294 RBL 1 WL 208 IAW SRM 51-40-02;[03] RECEIVED; LOCATED AND DRILLED NEW INTERCOSTAL P/N 141A5410U3AAR. LOT #1534252-1. IAW SRM 51-40-05 AND DWG 141A5400 REV: -<BR>OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION STEPS 1-3.;[05] VERIFIED MEASUREMENT TABLE.;[06] VERIFIED COMPLETION OF CORRECTIVE ACTIONS 1-3.<BR>OK TO INSTALL INTERCOSTAL GIVEN;[07] INSTALLED NEW INTERCOSTAL BS 277-294 RBL 1 WL 208 P/N 141A5410U3AAR LOT#1534252-1 PO#928536/1 IAW SRM 51-40-02 AND DWG 141A5400 REV:-;[08] VERIFIED CORRECTIVE ACTION STEP 7.;[09] VERIFIED COMPLETION OF CORRECTIVE ACTIONS 7 AND MEASUREMENT TABLE.