What was found
CRACKED ATTACH ANGLE ON CABLE GUARD INTERCOSTAL STA 691; RBL 1; WL 204-208.<[01] FABRICATED ATTACH ANGLE ON CABLE GUARD INTERCOSTAL STA 691; RBL 1; WL 204-208 FROM BAC1490-2782; LOT#1482272-2 IAW SRM 51-40-05-0G-0 AND DWG 237A9112; OK TO APPLY CHEMICAL CONVERSION AND PRIMER;[02] UPDATED STEP 1.;[03] VERIFIED CORRECTIVE ACTION 1. OK TO APPLY CHEMICAL CONVERSION AND PRIMER.;[04] APPLIED CHEMICAL CONVERSION COAT AND PRIMED ATTACH ANGLE FOR BS 691; RBL 1; WL 204-208 IAW SRM 51-20-01-0G-0 OK TO INSTALL;[05] VERIFIED CORRECTIVE ACTION #4.<BR>VERIFIED OK TO INSTALL NEW ATTACH ANGLE.;[06] REMOVED DAMAGED ANGLE DUE NOT LIMITS ON SRM; PART REPLACENT IAW SRM 51-10-02-0G PAR 9. AND INSTALLED NEW ATTACH ANGLE ON CABLE GUARD INTERCOSTAL AT STA 691; RBL1; WL204-208 IAW SRM 51-40-02-0G-0 AND AIPC 32-34-51-05.;[07] CORRECTION: REMOVED DAMAGED ANGLE DUE NOT LIMITS ON SRM; PART REPLACENT IAW SRM 51-10-02-0G PAR 9. AND INSTALLED NEW ATTACH ANGLE ON CABLE GUARD INTERCOSTAL AT STA 691; RBL1; WL204-208 IAW SRM 51-40-02-0G-0 AND DWG 273A911.;[08] VERIFIED CORRECTIVE ACTION #7.<BR>VERIFIED COMPLETE STEP 1.