As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
CABIN FLOOR PANEL 221BF HAS PULLED THROUGH INSERTS<[01] CORRECTIONS MADE TO STEPS 8;9 & 10 PREPARATION & APPLICATION OF PLIES TO THE OPPOSITE SURFACE.;[02] REPAIRED DAMAGED PULLED THROUGH INSERTS LOCATIONS ON CABIN FLOOR PANEL 221BF IAW SRM 53-00-50-2R-6.;[03] VERIFIED CORRECTIVE ACTION 2 & CURE SHEETS.