What was found
AREA AFT OF FORWARD CARGO BAY HAS A CRACKED STR AT THE AFT FASTENER. BS 500D+19; STR 25L<[01] PERFORMED CUT OUT DAMAGE SECTION S-25L AT FCB BS 500D+10 IAW SRM 53-00-03-2R-1 REPAIR 1;[02] VERIFIED CORRECTION ACTION ITEM 1.;[03] PARTIAL STEPS 1-2;[04] REQ. NDI CUT OUT FOR FREE CRACK CONDITION AND NOT MORE DAMAGE NOTE;[05] NDT HFEC INSPECTED CUT OUT AREAS IAW 737 NDTM PART 6 51-00-00 PROC 23. NO CRACKS NOTED. <BR>EQUIP USED: NORTEC 600 ATS1465 DUE 09/23;[06] PERFORMED REPAIR ON STRINGER 25LH PER REF SRM 53-00-03-2R-1<BR><BR>ALL STEPS COMPLETED;[07] VERIFIED STEP 1;2;3; COMPLETE.;[08] VERIFIED STEPS 4;5 AND MEASUREMENT TABLE CARD COMPLETE.