What was found
CORROSION FWD CARGO COMPARTMENT AFT BILGE FLOOR SUPPORT ANGLE FROM S-26L TO S-26R STA 500I MKD DOT<[01] FOUND EXFOLIATED CORROSION OUT OF LIMITS PER SRM 53-30-08-1A-1<BR>REMOVED RAIL FWD CARGO COMPARTMENT AFT BILGE FLOOR SUPPORT ANGLE FROM S-26L TO S-26R STA 500I PER SRM 51-40-02-0G-0<BR>LOCATED AND DRILLED NEW RAIL PN:143A9485-37 PER SRM 51-40-05-0G-0<BR>INSTALLED FWD CARGO COMPARTMENT AFT BILGE FLOOR SUPPORT ANGLE FROM S-26L TO S-26R STA 500I PER SRM 51-40-02-0G-0;[02] VERIFIED ALL STEPS<BR>ADDING REFERENCE SRM 53-00-53-1A-1 AND DWG 143A9481