What was found
CRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 RBL 1 AT FWD GALLEY AREA 2023-447488<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24.;[02] REPLACED WEB AND FASTENER LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 RBL 1 AT FWD GALLEY AREA I.A.W SRM B737-700 51-40-02 AND DRAWING 141A5400 REV:-;SEE INDIVIDUAL SIGN OFFS BELOW;[03] REPLACED WEB AND FASTENER LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 RBL 1 AT FWD GALLEY AREA I.A.W SRM B737-700 51-40-02 AND DRAWING 141A5400 REV:-;SEE INDIVIDUAL SIGN OFFS BELOW<BR>RII CERTIFIED