What was found
CRACK ON WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 LBL 32 AT FWD GALLEY AREA 2023-447491<[01] REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 LBL 32 AT FWD GALLEY AREA. IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET: 24 REV: A. SEE INDIVIDUAL SIGNOFF BELOW.;[02] TASK CARD COMPLETED <BR>REPLACED WEB INTERCOSTAL LOCATED FLOOR STRUCTURE BTW BS 277 TO BS 294.5 LBL 32 AT FWD GALLEY AREA. IAW B737-700 SRM 51-40-02 AND DWG 141A5400 SHEET: 24 REV: A. SEE INDIVIDUAL SIGNOFF BELOW.<BR>RII