What was found
CRACK ON BREAK PANEL AT FASTENER BS 540; LBL 1; WL 207<[01] REMOVED BREAK PANEL ON BS 540; LBL 1; WL 207 FOUND PART HAS NOT SRM LIMITS AND SO PART IS REPAIRABLE BY REPLACENENT IAW SRM 51-10-02 STEP 9;[02] LOCATED AND DRILLED NEW BREAK PANEL ON BS 540; LBL 1; WL 207 P/N 143A5240U33 LOT 1535018-1 AND 143A5240U11 IAW SRM 51-40-02 AND DWG143A5240. <BR>PK TO INSTALL;[03] VERIFIED CORRECTIVE ACTION STEPS 1-2. VERIFIED OK TO INSTALL.;[04] INSTALLED NEW BREAK PANEL P/N 143A5240U33 ON BS 540; LBL 1; WL 207 IAW SRM 51-40-02 AND DWG 143A0060.;[05] VERIFIED CORRECTIVE ACTION 4;[06] COMPLETED STEP 1