As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
AFT DROPDOWN PANEL EMERGENCY EXIT SIGN HAS 4 EA BURNED OUT BULBS R/H LOWER SIDE.<[01] RELAMPED 4 EA LIGHTS ON THE R/H LOWER SIDE OF AFT DROPDOWN PANEL EMERGENCY EXIT SIGN PER AMM 33-51-01-960-801 STEP 2.C.(1)(A) AND (C).;[02] VERIFIED CORRECTIVE ACTION 1;[03] COMPLETED STEP 1; PERFORMED GOOD OPERATIONAL TEST OF THE AFT DROPDOWN PANEL EMERGENCY EXIT SIGN PER AMM 33-51-01-960-801 STEP 2.C.(2)