CRACKED INTERCOSTAL BS 328-344 LBL 45 WL 208.<[01] VERIFIED APPLICABILITY FOR ALLOWABLE DAMAGE LIMITS IAW SRM 53-10-51-1A-1 ALLLOWABLE DAMAGE 1 AND IDENTIFICATION IAW SRM 53-10-51-01-2 IDENTIFICATION 2.<BR>EVALUATED CRACKED INTERCOSTAL L: 0.900' AND FOUND OUT ALLOWABLE DAMAGE LIMITS IAW SRM 53-10-51-1A-1 ALLLOWABLE DAMAGE 1 FIGURE 105 DETAIL A AND K. TOOL USED CALIPER ID: ATS2883 CAL DUE 04/024;[02] REMOVED INTERCOSTAL LOCATED AT BS 328-344 LBL 45 WL 208 IAW SRM 51-40-02;[03] RECEIVED; LOCATED AND DRILLED NEW INTERCOSTAL BS 328-344 LBL 45 WL 208 P/N 141A5410U16. LOT #1535380-1 PO#931623/1 IAW SRM 51-40-05 AND DWG 141A5400 REV: -<BR>OK TO INSTALL;[04] VERIFIED CORRECTIVE ACTION STEPS 1-3.;[05] INSTALLED NEW INTERCOSTAL BS 328-344 LBL 45WL 208 P/N 141A5410U16 LOT#1535380-1 PO#931623/1 IAW SRM 51-40-02 AND DWG 141A5400 REV:-;[06] VERIFIED CORRECTIVE ACTION STEP 5.;[07] VERIFIED COMPLETION OF CORRECTIVE ACTIONS 6 AND MEASUREMENT TABLE.