What was found
CORROSION ON BS 986 FLOOR BEAM RBL 44 WL 208.<[01] VERIDIED APPLICABILITY FOR ALLOWABALE DAMAGE LIMITS IAW SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1 AND IDENTIFICATION IAW 57-70-51-0I-1 IDENTIFICATION 1;[02] REMOVED NUT PLATE LOCATED AT BS 986 FLOOR BEAM RBL 44 WL 208. IAW SRM 51-40-02.<BR>REMOVED CORROISON ON BS 986 FLOOR BEAM RBL 44 WL 208. DIMENSIONS L:1' W: .700' DEPTH :0.035' IAW SRM 51-10-02 PARAGRAPH 15.<BR>EVALUATED REWORKED AREA; ORIGINAL THICKNESS 0.150' REMAINING THICKNESS: -115' FOUND OUT ALLOWABLE DAMAGE LIMITS IAW SRM 53-70-51-1A-1 ALLOWABLE DAMAGE 1. FIGURE 103 DETAIL E.<BR>TOOL USED MICROMETER ATS599 DATE DUE :09/2023;[03] VERIFIED APPLICABILITY FOR REPAIR AT BS 986 FLOOR BEAM RBL 44 WL 208 IAW SRM 53-70-51-2R-6 REPIAR 6. ALTERNATIVE 3;[04] VERIFIED CORRECTIVE ACTION STEPS 1-3.;[05] VALIDATED APPLICABILITY OF AWD AND REPAIR PER SRM 53-70-51-2R-6.<BR>VERIFIED COMPLETION OF CORRECTIVE ACTIONS 2.;[06] VERIFIED MAINTENANCE STEP 1.;[07] COMPLETED STEPS 1 AND 3.;[08] COMPLETED STEP 2.;[09] VERIFIED MAINTENANCE STEP 4.;[10] VERIFIED COMPLETION STEP 4;[11] VERIFIED MAINTENANCE STEPS 5 AND 6.;[12] VERIFIED MAINTENANCE STEP 3.;[13] UPDATED MEASUREMENT TABLE.;[14] COMPLETED STEP 5<BR>OK TO INSTALL STRAP GIVEN;[15] VERIFIED MAINTENANCE STEP 6.;[16] VERIFIED COMPLETION STEP 6;[17] VERIFIED MEASUREMENT TABLE.<BR>TASK COMPLETE