What was found
CORROSION ON AFT CARGO BAY INTERCOSTAL ANGLE BELOW SHIELD BS 767+2 RBL 21 WL 156<[01] VERIFIED STEP 1.<BR><BR>VERIFIED MEASUREMENTS TABLE.;[02] REMOVED INTERCOSTAL ANGLE BELOW SHIELD BS 767- 787 RBL 21 WL 156 PER SRM 51-40-02-0G-0.;[03] LOCATED; DRILLED; DEBURRED AND INSTALLED NUT PLATES ON NEW INTERCOSTAL ANGLE BELOW SHIELD BS 767-787 RBL 21; WL 156 PER SRM 51-40-05-0G-0; SRM 51-40-02-0G-0; DWG 146A8123; DWG 146A0081.;[04] VERIFIED CORRECTIVE ACTION #3.;[05] OK TO INSTALL INTERCOSTAL ANGLE BS 767-787 RBL 21 WL 156.;[06] VERIFIED OK TO INSTALL INTERCOSTAL ANGLE;[07] INSTALLED INTERCOSTAL ANGLE BELOW SHIELD BS 767-787 RBL21 WL 156 PER SRM 51-40-02-0G-0; DWG 146A8123.;[08] VERIFIED CORRECTIVE ACTION 7