What was found
AFT CARGO FLOOR BEAM CORROSION RBL 20 STA 807-827<[01] REMOVED DAMAGE I.A.W SRM 51-10-02. MEASURED DAMAGE REMOVED TO BE .012 INCHES IN DEPTH. DAMAGE FOUND TO BE OUT OF LIMITS AS GIVEN IN SRM 53-00-53-1A-2.;[02] LOCATED AND DRILLED NEW FLOOR BEAM STRAP I.A.W SRM 51-40-05.;[03] VERIFIED. LOCATED AND DRILLED NEW FLOOR BEAM STRAP I.A.W SRM 51-40-05.;[04] OK TO INSTALL LOCATED AND DRILLED NEW FLOOR BEAM STRAP.;[05] INSTALLED NEW FLOOR BEAM STRAP (146A8128-14) I.A.W SRM 51-40-02.;[06] INSTALLED NEW FLOOR BEAM STRAP (146A8128-14) I.A.W SRM 51-40-02. INSPECTION C/W.