What was found
CRACK INDICATION ON EXTERNAL SKIN LOWER PANEL. LOCATED AT STAB STA 193.9 RIB AND 16 INCH. FROM FRONT SPAR. INBOARD SIDE OF RIB. CRACK LENGTH = 0.900 INCH. APPROX. AT RT HORIZONTAL STABILIZER 2023-461062<[01] TOOL USED: ET EQUIPMENT P/N: NORTEC 500D; S/N: N500X12101V022233; DUE DATE: 30-AUG-23;[02] REPAIRED LOWER SKIN LOCATED RIB STATION 193.9 AND 16 INCH FROM FRONT SPAR RT HORIZONTAL STABILIZER IAW SRM B737-700 55-10-01-2R-11 REPAIR 11 SEE INDIVIDUAL SIGN OFF BELOW;[03] JOB COMPLETED AND CERTIFIED RII.