What was found
CUSTOMER REQUEST - CRACK ON VAPOR BARRIER LOCATED BS 663 LH SIDE AT MAIN WHEEL WELL COMPARTMENT 2023-461131<[01] TOOL USED CALIPER P/N: 500-464; S/N B17030933; DUE DATE: 17-OCT-23.;[02] TOOL USED HOT BONDER P/N HCS9200B-AV; S/N 18196127; DUE DATE: 22-JAN-24.;[03] TOOL USED: SCALE: P/N: CR5200; S/N: 8343110809; DUE DATE: 21-FEB-24;[04] TOOL USED: ULTRASONIC FLAW DETECTOR: P/N: EPOCH 650; S/N: 201036102; DUE DATE: 16-SEP-23.;[05] REPAIRED VAPOR BARRIER LOCATED BS 663 LH SIDE AT MAIN WHEEL WELL COMPARTMENT IAW B737-700 SRM 51-70-04-2R-10 REPAIR 10. SEE INDIVIDUAL SIGNOFFS BELOW.;[06] JOB TASK COMPLETED. RII INSPECTION COMPLETED.