What was found
CRACK WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN STA277 TO STA294.5 AND BL0 WL208.1 FWD GALLEY AND LAV 2023-461426<[01] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN STA 312 TO STA 328 AND RBL 31; WL208.1 FWD GALLEY AND LAV NEW IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND AND DWG 141A5400; SHEET 20; REV - A SEE INDIVIDUAL SIGN OFF BELOW;[02] REPLACED WEB - INTERCOSTAL FLOOR STRUCTURE LOCATED BETWEEN STA 312 TO STA 328 AND RBL 31; WL208.1 FWD GALLEY AND LAV NEW IAW B737-700 SRM 51-10-02 Ï¿½TEM 9 AND AND DWG 141A5400; SHEET 20; REV - A SEE INDIVIDUAL SIGN OFF BELOW. RII