What was found
CRACK ANGLE FLOOR STRUCTURE LOCATED BETWEEN STA927 TO STA947.5 AND BL 0; WL208.1 AT AFT GALLEY AREA 2023-461467<[01] TOOLS USED: TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 142811020; DUE DATE: 25-JAN-24; TEMPERATURE CONTROLLER: P/N: P3015GOES00000; S/N: 112820025; DUE DATE: 01-FEB-24.;[02] REPLACED ANGLE FLOOR STRUCTURE AND FASTENERS LOCATED BETWEEN STA927 TO STA947.5 AND BL 0; WL208.1 AT AFT GALLEY AREA IAW B737-700 SRM 51-40-02;SRM 51-10-02 AND DWG 147A5400 SHEET 22 REV. -. SEE INDIVIDUAL SIGN OFF BELOW.;[03] RII ITEM <BR>REPLACED ANGLE FLOOR STRUCTURE AND FASTENERS LOCATED BETWEEN STA927 TO STA947.5 AND BL 0; WL208.1 AT AFT GALLEY AREA IAW B737-700 SRM 51-40-02;SRM 51-10-02 AND DWG 147A5400 SHEET 22 REV. -. SEE INDIVIDUAL SIGN OFF BELOW.